Skip to main content
LIOMO

06 · Energy Management Systems

Know where every kilowatt-hour goes, and when

A LIOMO energy system connects meters, inverters, batteries and building controls to one platform, so your team can see consumption as it happens, act before demand peaks and report on energy from measured data.

Availability

Delivered as a project

Designed, installed and integrated for each building or site by LIOMO, from meter selection to software and ongoing support.

Illustrative interface · demo data. An energy management overview showing power flowing from the grid, rooftop solar and a battery into a building's loads: heating and cooling, lighting, two tenants and EV charging. A daily demand curve stays below a dashed peak limit.

The problem

One bill, no breakdown

Most sites know what they pay for energy each month, but not where it is used, when or why. The bill arrives as a single total, weeks after the consumption that caused it.
  • 01

    No breakdown by area

    A single main meter cannot tell you which building, floor, production line or tenant is driving consumption.

  • 02

    Peaks seen only on the bill

    Demand charges are set by short spikes, often when several large loads start together, and nobody sees them happen.

  • 03

    Generation and storage out of view

    Solar inverters, batteries and the grid connection each have their own display or app, so nobody sees the combined picture.

  • 04

    Audits built by hand

    Energy audits and sustainability reports depend on spreadsheets pieced together from bills, manual readings and estimates.

The solution

Metering, visibility and control in one system

A LIOMO energy system brings together the meters, generation, storage and building controls on a site, collects their readings in one place and turns them into live views, alarms and actions.
  • Sub-meters on the circuits, areas or tenants that matter, read automatically.
  • Live consumption, with solar, battery and grid flows shown side by side.
  • Demand tracked against limits you set, with alerts before a peak is reached.
  • Scheduled and rule-based control of HVAC, lighting and selected loads.
  • Interval data kept and organised for management reports and energy audits.

How it works

How a LIOMO energy system works

Every LIOMO system follows the same four stages. On an energy site, they look like this.
  1. 01

    Connect

    Sub-meters, current transformers, inverters, battery systems and building controllers are linked to a local gateway, typically over Modbus, M-Bus or BACnet, depending on what is already installed.

  2. 02

    Collect

    The gateway reads each device at regular intervals and sends timestamped readings to the platform, buffering them locally if the connection drops so no interval is lost.

  3. 03

    Understand

    Readings are organised by site, building, circuit and tenant, and turned into consumption profiles, demand curves, solar self-consumption and comparisons with previous periods.

  4. 04

    Act

    Alarms reach the right people, HVAC and lighting follow schedules and demand limits, and reports are ready for management, tenants and energy auditors.

Capabilities

What a project can include

What a LIOMO energy project can cover, depending on the site.
  • 01

    Site assessment

    A review of the electrical layout, existing meters, controls and bills, to decide where measurement will tell you the most.

  • 02

    Sub-metering

    Meter and current-transformer selection and installation coordination for circuits, floors, lines or tenants, with water, gas and heat meters where needed.

  • 03

    Real-time consumption

    Live and historical power and energy for every meter, with daily, weekly and monthly profiles and base load outside working hours.

  • 04

    Solar, battery and grid

    Generation, battery state of charge and grid import and export on one screen, to see how much of your own energy you actually use.

  • 05

    Peak-demand management

    Demand tracked against a limit you set, with early alerts and, where agreed, staged switching of non-critical loads.

  • 06

    HVAC and lighting control

    Schedules, setpoints and occupancy rules applied through existing building controls, or through new controllers where none exist.

  • 07

    Alarms

    Notifications for abnormal consumption, out-of-hours use, equipment faults and meters that stop reporting.

  • 08

    Reports for audits

    Periodic reports per site, building or tenant, with interval data exports for energy audits and sustainability reporting.

  • 09

    Integration

    Energy data shared with building management, finance or reporting systems through APIs or scheduled file exports.

Use cases

Where it fits

Energy systems suit any organisation with significant energy bills that wants to know what drives them.
  • Commercial and office buildings

    Meter floors and tenants separately, run HVAC and lighting to occupancy, and recharge energy costs from measured data.

  • Industrial and production sites

    See consumption per line or machine, find base load outside production hours, and manage demand when large loads start.

  • Sites with solar and storage

    Follow generation, battery state and grid exchange together, and check that the installation performs as designed.

  • Multi-site organisations

    Compare branches, shops or facilities on the same basis and find the sites that use more than they should.

Business value

What it changes for the business

The aim is to make energy a cost you manage with data, not one you only read on a bill.
  • 01

    Less energy wasted

    Out-of-hours consumption, equipment left running and a creeping base load become visible, so they can be dealt with.

  • 02

    Control of demand charges

    Seeing peaks as they build, and shifting loads where agreed, helps keep demand within the limits you set.

  • 03

    Fair cost allocation

    Sub-metered data lets you assign energy costs to departments, tenants or products from records instead of estimates.

  • 04

    Audit-ready records

    Interval data and consistent reports make energy audits and sustainability reporting quicker to prepare and easier to check.

FAQ

Questions buyers ask

Can you work with the meters and controls we already have?

Often, yes. Many existing meters, inverters and building controllers share data over open protocols such as Modbus, M-Bus or BACnet. The site assessment checks what each device can provide, and new meters are added only where existing ones cannot give the data you need.

Does installing sub-meters mean shutting down power?

It depends on the meter type and the electrical installation. Split-core current transformers can often be fitted without interrupting supply, while some meters need a short, planned shutdown. Any electrical work is planned with your facilities team and carried out by qualified electricians.

Can the system switch loads automatically?

Yes, where you want it to. Control is agreed load by load: which equipment may be switched or adjusted, under what conditions, and how it can be overridden by hand. Many sites start with monitoring and alarms, then add control once the data shows where it is worthwhile.

Will the data help with an energy audit?

It gives auditors measured interval data by area and by load instead of estimates, and the data can be exported as spreadsheets for their analysis. The system supports an audit; it does not replace the auditor.

How long does a project take?

It depends on the number of sites, the meters and controls already in place and the integration needed. A typical sequence is a site assessment, a design and quotation, installation and commissioning, then a period of tuning alarms and reports with your team.

Discuss Energy Management Systems for your operation

Tell us what you run and what you need to see. We will show you how it would work, with no obligation.